Our work
Every photo here was taken by our crew on a Metal Men job. Click any picture to see it full size with its description.
Packaged Rooftop Unit Crane Set
A packaged rooftop unit replacement set by crane onto new structural steel. The crew staged the lift from the lawn, rigged the unit on a spreader bar, and landed it on its rails in a single morning.
Corridor Piping & Wall Penetrations
Overhead piping work in an occupied building corridor, with containment up and the hallway kept open. New runs pass through block walls, and each penetration is sleeved, packed, and closed with new block and mortar.
Steam Valve & PRV Replacement
Replacement of aging steam valves in a pipe trench: new flanged gate valves, a Y-strainer with blowdown, and a pressure reducing valve, all tied into the existing main with new black steel pipe.
Cooling Tower Piping & Valve Manifold
Supply and return piping for a BAC cooling tower, with a flanged butterfly valve manifold at grade and PVC risers over the top of the tower.
Laboratory Exhaust Ductwork
Welded stainless steel exhaust ductwork for a laboratory building: risers through the penthouse floor grating, a labeled header, and stainless hooded vents on the roof.
Commercial Kitchen Exhaust System
A complete commercial kitchen exhaust system: stainless hood, welded grease duct, fire suppression, and the rooftop exhaust equipment set by crane.
Base-Mounted Pump Replacement
Two base-mounted pumps replaced in a central plant, set on housekeeping pads with suction diffusers and the piping repainted and insulated.
Central Plant Piping & Controls
Distribution piping and control valves in a central plant: insulated mains on pipe stands, with isolation, strainers, gauges, and actuated valves on each branch.
Overhead Steam Line Replacement
A section of overhead steam piping replaced in black steel: welded flanges, new hangers, then insulation and PVC jacketing once the line was proven.
Chilled Water Control Valve Replacement
An actuated control valve replaced on an overhead chilled water line, flanged into the existing insulated piping and wired back to the building controls.
Laboratory Ceiling & Air Distribution
Ceiling grid, lighting, and air devices put back in a teaching laboratory after mechanical work above the ceiling.
Lab Support Fan Coil Closet
A fan coil unit and its copper piping in a small lab support closet, serving the corridor where the ultra-low freezers live.
Above-Ceiling Duct & Pipe Rough-In
Spiral duct and copper line sets routed above a ceiling between existing plumbing and sprinkler lines, all hung and supported before close-in.
Mechanical Room Assessments
Walkthroughs of two mechanical spaces ahead of scoped work: an electrical and piping room, and a long utility corridor of air handlers.
Field Details
Two details from different jobs: a strut hanger assembly and a gasketed duct access door. Small work that the finished job depends on.